13
Then connect the earthing-type plug to a
socket-outlet with an earthing contact and pro-
tective earthing.
Warning!
There must be no break in the protective con-
ductor/earth connection inside the appliance, in
the power cord or in the socket-outlet because
any discontinuity in the protective conductor
would create a risk of fatal injury.
c) Actuate the power ON/OFF switch (1). After
roughly 30 s, slowly turn the INTEN knob (2) to
the right until the trace becomes visible on the
screen. Then set the desired brightness level.
NOTE:
Do not leave the brightness set to maximum for
any length of time in the absence of a signal.
Above all, note that no spot is visible on the
screen (= no horizontal sweep) immediately
after powering-up. Otherwise the electron
beam or spot will burn the CRT's internal
coating, thus damaging it.
d) Use the FOCUS knob (3) to adjust the trace
focus.
e) Then use the CH-1 POSITION knob (16) to
move the trace so that it coincides with the
horizontal centre line.
f) If the trace does not coincide exactly with the
centre line, adjust it by using a suitable
screwdriver to operate the ROTATION control
(5).
g) Use the POSITION knob (25) to align the trace
horizontally and centrally.
POWER switch (1) : OFF (not depressed)
INTEN (2) : set to left-hand stop
FOCUS (3) : set to middle position
AC/GND/DC switch (10)+(11) : set toAC
VOLTS/DIV switch (12)+(13) : set to 20 mV position
POSITION 16)+(17) : middle position, depressed
VARIABLE (14)+(15) : set to right-hand stop, depressed
vertical mode switch (18) : set to CH 1 position
TIME/DIV switch (20) : set to 0,5 ms
VARIABLE knob (24) : set to right-hand stop, depressed
Horizontal POSITION (25) : set to middle position
Trigger MODE switch (26) : set to AUTO
Trigger SOURCE switch (27) : set to CH 1
Trigger LEVEL (29) : set to middle position
HOLDOFF knob (28) : set to NORM position = left-hand stop
Comentarios a estos manuales